Acuros XB for dose calculations in external beam photon radiotherapy-mini review

  • Jung-ho Park Suncheon University, Suncheon, Jeollanam-do, South Korea

Abstract

Dose calculations based on Monte Carlo (MC) often require sophisticated treatment planning stations with long processing time, and this could be issue for many cancer centers. Hence, most of the commercial treatment planning system include faster dose calculation engines for the daily clinical routine. Due to advancement in technology and computing power, it is now possible to implement MC based dose calculation algorithms in the clinical environment. This report summarizes the major findings of various researchers who have investigated Acuros XB algorithm, which is the MC based dose calculation algorithm commercially available for dose calculations in radiotherapy.

Reference

[1]
Lu L. Dose calculation algorithms in external beam photon radiation therapy. Int J Cancer Ther Oncol 2013; 1(2):01025.
[2]
Han T, Followill D, Mikell J, Repchak R, Molineu A, Howell R, Salehpour M, Mourtada F. Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer. Med Phys. 2013; 40(5):051710.
[3]
Kan MW, Leung LH, So RW, Yu PK. Experimental verification of the Acuros XB and AAA dose calculation adjacent to heterogeneous media for IMRT and RapidArc of nasopharygeal carcinoma. Med Phys. 2013 Mar; 40 (3): 031714.
[4]
Stathakis S, Esquivel C, Quino L, Myers P, Calvo O, Mavroidis P, Guti?rrez A and Papanikolaou P. Accuracy of the Small Field Dosimetry Using the Acuros XB Dose Calculation Algorithm within and beyond Heterogeneous Media for 6 MV Photon Beams. Int Jour of Med Phys Clin Eng Radiat Onc 2012; 1 (3): 78-87.
[5]
Ojala JJ, Kapanen MK, Hy?dynmaa SJ, Wigren TK, Pitk?nen MA. Performance of dose calculation algorithms from three generations in lung SBRT: comparison with full Monte Carlo-based dose distributions. J Appl Clin Med Phys. 2014; 15(2):4662.
[6]
Kroon PS, Hol S, Essers M. Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plans. Radiat Oncol. 2013; 8(1):149.
[7]
Kathirvel M, Subramanian S, Clivio A, et al. Critical appraisal of the accuracy of Acuros-XB and Anisotropic Analytical Algorithm compared to measurement and calculations with the compass system in the delivery of RapidArc clinical plans. Radiat Oncol 2013; 8:140.
[8]
Liu HW, Nugent Z, Clayton R, Dunscombe P, Lau H, Khan R. Clinical impact of using the deterministic patient dose calculation algorithm Acuros XB for lung stereotactic body radiation therapy. Acta Oncol. 2013 Aug 19. [Epub ahead of print]
[9]
Fogliata A, Nicolini G, Clivio A, Vanetti E, Cozzi L. Critical appraisal of Acuros XB and Anisotropic Analytic Algorithm dose calculation in advanced non-small-cell lung cancer treatments. Int J Radiat Oncol Biol Phys. 2012; 83(5):1587-95.
[10]
Rana S. Clinical dosimetric impact of Acuros XB and analytical anisotropic algorithm (AAA) on real lung cancer treatment plans: review. Int J Cancer Ther Oncol 2014; 2(1):02019.
[11]
Ojala J. The accuracy of the Acuros XB algorithm in external beam radiotherapy ? a comprehensive review. Int J Cancer Ther Oncol 2014; 2(4):020417.
[12]
Chetty IJ, Curran B, Cygler JE, et al. Report of the AAPM Task Group 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med Phys. 2007; 34(12):4818?53.

Downloads

Download data is not yet available.
  • Views 262
  • Downloads 363
  • Citations 0
  • Shares 0
Published
December 30, 2014
How to Cite
PARK, Jung-ho. Acuros XB for dose calculations in external beam photon radiotherapy-mini review. Trends Journal of Sciences Research, [S.l.], v. 1, n. 1, p. 26-27, dec. 2014. ISSN 2377-8083. Available at: <http://www.tjsr.org/journal/index.php/tjsr/article/view/6>. Date accessed: 09 july 2020.